Please fill in the Enquiry Form at the end of the page to
request more details on any of the listed power plants.
Prices are NEGOTIABLE depending on speed and ease of
transaction. We will do our very best to satisfy your requirements
and can provide basic project consultation provided that the
project is real and funds are shown to be available.
Click the
icon for more information
| REF. | No.
Units | MW | Mnf. | Type of Plant | Hz | kV | Fuel | Condition/
Hours | Price per
EACH unit | |
| 467CP | 1 | 800 | GE | Combined Cycle
Frame 9FA | 50 | - | Dual fuel | UNUSED | $140,000,000 | admin: L21 0823
- GE Frame 9FA Combined Cycle Plant, 800MW, 50Hz
- Boiler:
- Steam Turbine: GE D11
- Fuel: Dual fuel
- Voltage:
- Frequency: 50 Hz
- Year:
- Condition: UNUSED
- Location: Asia
- Other: DLN. Test hours only.
|
| 479CP | 1 | 445 | Siemens | Combined Cycle
V94 | 50 | - | NG | USED | $29,200,000 | admin: L26
- 1 x Siemens V94 Combined Cycle plant, 445MW, 50 Hz
- Model: V94
- Fuel: Natural gas
- Voltage:
- Frequency: 50 Hz
- Year: 2009
- Condition: USED, 30,000 hours
- Location: Asia
- Other:
|
| 492CP | 5 | 12.2 | Siemens | Combined Cycle
SGT 300 DLE | 50 | 10,500 | Dual fuel | NEW | $7,100,000 | admin: L10 0525
- 5 (Five) x Siemens SGT300 DLE Combined Cycle Plants, 12.2 MW, 50Hz
- Gas Turbine: SGT300 DLE, 8.3 MW
- Steam Turbine: 4 MW
- Fuel: Dual fuel
- Voltage: 10,500 volts
- Frequency: 50 Hz
- Year: 2021
- Condition: NEW
- Location: Asia
- Other: 5 plants, each with 1 gas turbine and 1 steam turbine
|
| 494CP | 1 | 12 | Biomass | Biomass RDF CHP | 50 | 11,000 | Biomass | USED | EUR 1,650,000 | admin: L32 0825
- 1 x Biomass RDF CHP Plant, 12 MW, 50Hz
- Details: 10MW Thermal, 2MW Electrical Steam turbine
- Fuel: Biomass
- Voltage: 11,000 volt
- Frequency: 50 Hz
- Year: 1999
- Condition: USED
- Location: Europe
- Other:
|
| 496CP | 1 | 810 | GE | Combined Cycle
Frame 9FA | 50 | 15,750 | NG | USED | EUR 182,000,000 | admin: L11
- GE Frame 9FA, Combined Cycle Plant, 810 MW, 50Hz
- Gas Turbine: Frame 9FA
- Steam Turbine: Alstom
- Fuel: Natural gas
- Voltage: 15,750 volt
- Frequency: 50 Hz
- Year:
- Condition: USED, 3,000 hours
- Location: Asia
- Other: DLN
|
| 497CP | 1 | 12.5 | MAN | Biomass CHP Plant | 50 | 6,300 | Biomass | USED | EUR 3,650,000 | admin: L31 0226
- 1 x Biomass CHP Plant, 12.5 MW, 50Hz
- Details: 12.5 MW Thermal, 5 MW Electrical Steam turbine
- Fuel: Biomass
- Voltage: 6,300 volt
- Frequency: 50 Hz
- Year: 2009
- Condition: USED
- Location: Europe
- Other: MAN Steam Turbine, 3 x boilers
|
| 498CP | 1 | 81 | Rolls Royce | Combined Cycle
Trent 60 | 50 | 10,500 | NG | USED | $ 14,600,000 | admin: L9
- 1 x Rolls Royce Trent 60 Combined Cycle plant, 81 MW, 50Hz
- Model: Trent 60
- Fuel: Natural gas
- Voltage: 10,500 volt
- Frequency: 50 Hz
- Year:
- Condition: USED. 20,000 hours
- Location: Asia
- Other:
|
| 499CP | 1 | 7 | VAS | Biomass CHP Plant | 50 | - | Biomass | UNUSED | - | admin: L32D
- 1 x VAS Biomass CHP plant, 7 MW, 50Hz
- Details: 6MW thermal, 1MW electrical
- Fuel: Biomass
- Voltage:
- Frequency: 50 Hz
- Year: 2003
- Condition: UNUSED.
- Location: Europe
- Other: Complete plant
|
| 500CP | 1 | 250 | GE Alstom | CHP Plant
Frame 9 | 50 | 11,500 | Dual fuel | USED | $ 71,500,000 | admin: L3
- 1 x GE Alstom Frame 9 CHP plant, 250 MW, 50Hz
- Model: Frame 9 model 9171 gas turbines
- Details: 2 x gas turbines, 1 x HRSG
- Fuel: Dual fuel
- Voltage: 11,500 volt
- Frequency: 50 Hz
- Year: 2000
- Condition: USED, 50,000 hours.
- Location: Europe
- Other:
|
| 501CP | 1 | 243 | GE Alstom | CHP Plant
Frame 9 | 50 | 11,500 | Dual fuel | USED | OFFER | admin: L14
- 1 x GE Alstom Frame 9 CHP plant, 243 MW, 50Hz
- Model: Frame 9 gas turbines
- Details: 2 x gas turbines, 1 x HRSG
- Fuel: Dual fuel
- Voltage: 11,500 volt
- Frequency: 50 Hz
- Year: 1995
- Condition: USED, 150,000 hours.
- Location: Asia
- Other:
|
ENQUIRY FORM for further information
Your details will be kept private and will be used only for the purposes of replying to your enquiry.
All equipment is available for sale at the time of publication. Confirmation of sold/unsold status will be confirmed at the time of enquiry.
Disclaimer – Although the statements and technical information contained within these new & used Complete Plants Sales Listings
are believed to be materially accurate, no guarantee is given as to the correctness of any of the information given.